Safety Position SwitchesThe best protection for personnel and processes
Reliable and tamper-proofSafety components reliably monitor and protect protective guards, doors and covers. Thanks to their multi-coded actuators they provide a high degree of protection against tampering. Equipped with double-break contacts, they are also suitable for use in the configuration of redundant safety circuits. It goes without saying that interlocked opposing contacts and positively-opening break contacts to IEC/EN 60 947-5-1 are provided and that the switches are suitable for use with electronic devices in accordance with IEC/EN 61 131-2, enabling the safe exchange of information with any controller. All operating heads on the safety components can be rotated through 4 × 90°. With the high degree of protection IP 65, the safety components ensure wide-ranging individual application. Caution: Any changes to the original Moeller safety position switches are strictly forbidden and lead automatically to the loss of all approvals!
LS-ZB and LS4-ZB Safety Position Switches
These safety position switches with separate actuators provide protection for personnel: if the protective guard is opened, they disconnect the power and in so doing, remove the danger. Further advantages of LS4-ZB
Further advantages of LS-ZB
LS-ZBZ – Securing and Interlocking
Using the magnet-powered design, the protective cover is interlocked when operational voltage is applied, and can therefore be opened directly in the event of power failure. The spring-powered scheme ensures that the door or protective guard remains safely locked even in the event of power failure. The interlock is released when power is applied to the LS-ZBZ. This means that personnel are protected from overrunning machines. This variety of the LS-ZBZ only opens once the potentially dangerous movement has ceased. In an emergency, the protective guard can be opened using an auxiliary release mechanism. Via a second switching contact, dangerous processes can be monitored from the control station. Further advantages of LS-ZBZ
LSR/TS Hinge-operated and LSR/TKG Hasp-operated Switches
Where an attempt is made to open a protected door or flap during operation, the ATR/TS hinge-operated switches and the ATR/TK hasp-operated switches immediately disconnect the power supply to the machine or installation. Opening is registered at an angle of only 5°, and so even tampering is not possible.
Reliable safeguarding of hinged protective guards
Flexibility in all conditionsThe safety components can be fitted flush both in narrow style enclosures to EN 50 047, and in wide version enclosures. The operating head can be rotated through 4 x 90°. The actuating lever of the LSR/TKG hasp-operated switch can be easily converted on site to align with the position of the protective cover. This ensures optimum matching to the application in
question and facilitates selection when ordering.
|
|||||